When you need the inspection report
Inspecting the connection is a standard step that both the network operator and the authorities normally expect. Typical situations are:
- New connection: a new house, holiday cabin or workshop that gets its own supply point
- Replacing or rerouting the connection: a new cable, a different route or a new meter cabinet
- Repair after damage: for example when a digger has cut the cable. Simply joining it is not enough, the repair has to be confirmed by testing
- Raising the rating of the main circuit breaker or another change where the operator wants up-to-date proof of the condition
- Older properties where the customer changes and the operator has no reliable, current record
Every network operator has its own technical connection conditions. They set out things like the type and position of the supply cabinet and the exact point where your part ends and the operator's network begins. It is worth reading them before the connection is built. What the building authority will require at completion depends on local building regulations, so check directly with your local building authority.
How the inspection works step by step
An inspection is more than a quick look at the cable. The inspector reviews the paperwork, checks the installation and measures the electrical values with calibrated instruments. It usually goes like this:
- Request the documents: the design or a sketch of the connection, details of the cable and equipment used, photos of the trench before backfilling and any earlier inspection reports.
- Walk the route from the fuse or meter cabinet to the main board in the house and check that the enclosures match the documents, are closed, labelled and have a suitable protection rating for outdoor use.
- Confirm that the cable is suitable for burying in the ground and correctly sized for the main circuit breaker, and that ducts, wall entries and seals are in place where they can be seen.
- Measure the insulation resistance of the conductors, which shows whether the insulation is damaged or damp.
- Check the continuity of the protective conductors and the correct split of the combined PEN conductor into separate earth (PE) and neutral (N) at the point given in the design.
- Measure the earth fault loop impedance. This shows whether the breaker will switch off quickly enough if a fault occurs.
- Measure the earth electrode resistance and, if the board has residual current devices (RCDs), test that they trip.
- Write up the report with the results, a conclusion and any defects, then sign and hand it over.
An outdoor connection has to cope with moisture, frost and mechanical damage. That is why the inspector also pays attention to things that matter less inside the house: a sand bed under the cable, warning tape above it, ducts under driveways and paved areas, and a sealed cable entry into the building.
What the report should contain
A valid report follows the electrical installation standards in force in your country, which are usually based on the international IEC 60364 series and its European equivalent (HD 60364). Part 6 deals with verifying installations and Part 4-41 with protection against electric shock. The report should include:
- Identification of the building, the supply point and the type of inspection (for a new connection this is the initial verification)
- A description of the connection: cable type and cross-section, route length, installation method, enclosures and the rating of the main breaker
- The earthing system and the method of protection against electric shock
- Measured values and the instruments used
- A list of defects found and recommendations for putting them right
- A clear conclusion on whether the installation is safe to use
- The inspector's name, registration or certificate number and scope of qualification, plus the date, signature and stamp where required
If the report ends with a negative conclusion, the network operator will not energise the supply point. After the repair, the inspection has to be repeated.
What makes the inspection easier or harder
How demanding the inspection is, and so how long it takes and how much work it involves, depends mainly on what the inspector finds on site. It is simpler when:
- The connection is new and comes with a design and photos of the trench before backfilling
- The route is short and clear, and the enclosures are easy to reach
- The installer knows the local network operator's conditions
It gets harder with a long or unclear route, missing paperwork, an older connection with an unknown cable, an earth electrode that is hard to reach, or an urgent deadline. If the inspector finds faults, repairs and a repeat inspection follow. In practice it often happens that nobody took photos of the trench and the cable is already buried. The inspector then has no way to check how it was laid and may ask for a trial hole or a written declaration from the installer.
Typical faults that cause a connection to fail
- Poor or missing earthing. The earth electrode is not connected, the joints are corroded or the earth resistance is too high. Shock protection then does not work as it should.
- Undersized cable. The cross-section does not suit the main breaker or the length of the route. The cable can overheat and the loop impedance comes out too high.
- Wrong cable or poor installation. The cable is not rated for burial, or the sand bed, warning tape or duct under the driveway is missing.
- Unprofessional joints. The cable is connected to an old board without a breaker, temporary connectors are used, or a repair joint is not suitable for underground use.
- Missing documents. The owner brings only a statement that "an electrician did the wiring". That is not enough.
An informal opinion from an electrician who is not a qualified inspector carries no weight with the network operator or the authority. The inspector is personally responsible for the accuracy of the report. That is why it makes sense for the inspection to be done by someone other than the person who installed the connection.
How to check the report you receive
Before you attach the report to your connection application or completion paperwork, go through it point by point:
- The address, supply point and description of the connection match reality
- The cable type, cross-section and main breaker rating are stated
- The report contains actual measured values, not just a general statement
- The conclusion clearly says the installation is safe to operate
- If defects are listed, you have confirmation that they have been fixed
- The inspector's name, certificate number and qualification for low-voltage installations up to 1000 V are given
- The report has a date, a reference number and a signature
- You keep it on paper and electronically, together with photos of the cable route
Frequently asked questions
Formally, anyone with a valid inspector qualification can do it. An independent inspector is still the better choice, because they look for faults without a conflict of interest, and the network operator and authority accept their report without doubt.
For a family house the testing itself usually takes a few hours. Writing up the report typically takes several days, depending on how busy the inspector is. Book the inspector as soon as the connection is finished, not a week before completion.
The inspector describes them in the report together with recommendations on how to fix them. After the repair there is a follow-up check and a new or updated report. With a negative conclusion, the network operator will not energise your supply.
Periodic inspection intervals depend on local regulations and the conditions the installation is exposed to. You will certainly need a new inspection after any work on the connection, such as a repair, a new cable or a change of main breaker. In blocks of flats, the building management or owners' association keeps track of the intervals.
No. The connection inspection covers the section up to the main distribution board. The internal wiring, sockets and lighting circuits need their own inspection, which the building authority usually also expects at completion.