Building work price list: Fitting a Door Frame into a Drywall Partition - UA Profile Reinforcement
Enter quantities and the price recalculates instantly. You can adjust the rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
Plasterboard finishing cost | ||||
| Door frame reinforcement in plasterboard partition with UA profiles | pcs | €61.00 / pcs | pcs | enter quantity- |
| Plasterboard corner beads | lm | €2.50 / lm | lm | enter quantity- |
| Applying acrylic sealant to plasterboard joints and corners | lm | €1.10 / lm | lm | enter quantity- |
| Access hatches | pcs | €45.00 / pcs | pcs | enter quantity- |
| Cut-outs for light fittings in plasterboard | pcs | €11.50 / pcs | pcs | enter quantity- |
| Plasterboard niches and shelving | pcs | pcs | - | |
| Bespoke termination for LED strip / curtain track | lm | €24.00 / lm | lm | enter quantity- |
What UA profile reinforcement is and when it is needed
A door in a plasterboard partition needs more than a gap left between the ordinary studs. A door loads the partition every day. The leaf hangs on its hinges and strikes the frame when it closes. Each time, the whole frame vibrates slightly.
The reinforcement works like this. Thicker steel profiles are fixed on both sides of the opening and anchored to the floor and the ceiling. A rigid door head is formed between them above the door. The door frame or lining is then fixed to this frame. This work belongs to every new partition with a door and to any reconfiguration of the layout of a flat or house. It is one of the standard tasks in plasterboard work.
A standard partition is built on CW studs and UW tracks made of thin galvanised steel. They are fine for dividing a space. They cannot, however, cope with repeated loading at the hinges over the long term. If the door frame is fixed only to this kind of structure, it works loose over time. The door starts to drop and no longer closes properly. Cracks appear at the corners above the opening.
A UA profile looks similar to a CW stud. It is made of much thicker steel, typically around two millimetres according to the manufacturer. This makes it far stiffer, and it transfers the weight of the door and the impact of closing directly into the floor and ceiling.
When a CW stud is enough and when a UA profile is needed
Drylining system manufacturers' installation guides classify door openings by leaf weight and partition height. For light leaves and normal room heights, some systems allow CW studs. This is usually conditional on extra measures, such as a doubled stud or a timber batten inserted into the stud. In practice, a leaf weight limit of around 25 kg is often quoted for these solutions. The exact leaf weight and the heights of leaf and partition must always be taken from the guide for the specific system.
UA profiles are used whenever:
- the leaf is solid, heavier or glazed,
- the door is taller than standard or the partition is high,
- the frame is flush (non-rebated) or concealed, sitting flush with the wall,
- the weight of the future leaf is not yet known.
If in doubt, a UA profile is the safer choice. The partition will then also cope with a later change to a heavier door.
What to decide before fitting a door frame into plasterboard
The UA profile frame is built to suit a specific door frame. If decisions are postponed, the opening often does not fit and has to be altered. Before work starts, the following should be clear:
- type of frame: timber lining with architraves, steel frame designed for plasterboard, flush frame or concealed frame. Each needs a different opening size and a different fitting tolerance,
- leaf size and weight: width, height and whether it is a light hollow-core, solid or glazed leaf,
- finished floor level: the floor including screed, underlay and floor covering. The opening is measured from this level, not from the bare concrete,
- opening direction: which side the hinges are on and which way the leaf opens. It should not hit a light switch, radiator or furniture,
- switch and sockets next to the door: their position determines the cable routes in the partition. Recessed luminaires or speakers planned near the door should also be considered now, as cutting holes for luminaires, speakers and similar up to Ø15 cm must avoid the UA profiles. Wiring may only be connected by a qualified electrician,
- partition thickness: it must match the adjustment range of the door lining, otherwise the lining will not sit tight to the wall.
Sliding doors that disappear into the partition are a different case. They use a dedicated pocket door system, not a UA profile frame with a conventional door frame.
In a block of flats, it is worth informing the freeholder, managing agent or residents' management company before altering partitions, as the lease may require consent. For a more extensive alteration, check with local authority building control which procedure applies in your case. Do not assume that no approval is ever needed.
A plasterboard partition is not load-bearing in itself. It is, however, fixed to the ceiling and floor, which may well be load-bearing. Do not drill into them where services run or where the structure could be weakened. In homes built before 2000, have suspect materials tested before you drill or demolish; asbestos insulating board, lagging and sprayed coatings must be removed by an HSE-licensed contractor.
How the reinforcement is done step by step
The reinforcement is built while the partition is being erected, before boarding. In practice the process usually looks like this:
- Information: confirm the frame type and the finished floor level. The opening size follows from these.
- Setting out: mark the door centre line and the position of the opening on the floor and on the ceiling.
- Tracks: fix the top UW track to the ceiling along the full length of the partition. Fix the bottom UW track to the floor and leave it interrupted at the opening.
- Cutting: cut the UA profiles to the clear room height. Where they are fixed with connecting angles, the profile is cut a few millimetres shorter. The exact tolerance is given in the system guide.
- Positioning and fixing: insert the UA profiles on each side of the opening into the top and bottom UW tracks. Fix them to the floor and ceiling through the system connecting angles, using anchors suitable for the substrate.
- Checking: check plumb with a spirit level or laser. Measure the distance between the profiles at the top and the bottom.
- Door head: form the door head and connect it firmly to the side UA profiles.
- Studs above the door: add short CW studs above the head so the boards have something to be screwed to.
- Rest of the partition: add the remaining CW studs so that the UA profiles remain a separate load-bearing frame. Any planned shelves, niches or other recesses in the drywall should be framed at this stage too, away from the door frame.
- Boarding and jointing: board the partition following the rules for door openings. Fill and tape the joints and edges.
- Door frame: fit the door frame, align it and fix it according to the manufacturer's instructions. Hang the leaf and adjust the hinges.
When sizing the opening, allow for the fitting tolerance of the frame. Its exact value is given by the frame manufacturer. It differs for timber linings, flush frames and concealed frames.
The fixing method depends on the frame type. A steel frame for plasterboard is screwed directly to the UA profiles. It is often fitted while the partition is being built, before boarding. A timber lining is usually fitted after decorating. It is aligned in the opening with spacers and fixed with expanding foam according to the manufacturer's instructions. The UA profile frame gives it straight, rigid reveals.
Door head and boarding around the door
The door head is often underestimated, even though it is what holds the shape of the opening. It is usually made from a UW track. Its ends are cut and bent into a U shape. The resulting flaps are screwed to the side UA profiles. Some systems offer a dedicated connector for this joint, in which case that is used. For heavier or taller doors, the system may require a UA profile in the head as well, or a doubled solution. The joint must be square and must not sag. The same need for a rigid, accurate frame applies to bespoke window finishes for curtains or LED strips built in plasterboard.
One important rule applies to boarding: a board joint must never line up with the edge of the door opening. The boards around the door are therefore cut into an L shape. Alternatively, the joint above the opening is moved some distance to one side. A joint in line with the edge of the frame is the most common cause of cracks above the corner of a door.
With double-layer boarding, the joints in each layer are staggered. Boards are fixed into the UA profile with screws designed for heavier gauge steel, at the spacings given in the system guide. A standard plasterboard screw struggles to get through thick steel. It spins and the head does not sink properly. Narrow strips of plasterboard next to the opening are unnecessarily fragile. It is better to use a full board and cut the opening out of it.
Cost of fitting a door frame into plasterboard: what it depends on
The guide price for labour is €61.00 per piece, meaning per door opening. This price applies to the simplest case: a new partition, a level concrete floor, a solid ceiling and a frame type known in advance. In that case the reinforcement is a normal part of building the partition. The price increases mainly in these situations:
- retrofitting reinforcement in a boarded partition: the work is several times greater than in a new partition, because stripping out and reboarding are added,
- room height: long UA profiles are harder to set plumb. Scaffolding or a mobile platform is often needed,
- loft rooms: the partition meets a sloping ceiling or timber roof members. Profiles have to be cut at an angle and fixed differently,
- floating floor: the UA profile is not fixed into the screed but into the structural floor below. If the screed is already laid, it has to be cut at the fixing points,
- underfloor heating: before drilling, the exact pipe routes must be known. The simplest approach is to build the partition before the screed and connect the screed to it with an edge strip,
- timber joist ceilings or suspended ceilings: these are not suitable for fixing into. Structural fixing points have to be found or an auxiliary structure added,
- door type: heavy, tall or flush doors require greater accuracy and sometimes a reinforced head. Concealed frames are among the most demanding,
- materials: UA profiles cost more than CW studs. They also need system angles, anchors and screws for heavier gauge steel,
- scope of the item: a quote may cover only the frame, or also boarding, jointing and fitting the frame and leaf. When comparing quotes, ask exactly what the price includes.
What to have ready so the work does not stall
- the chosen and ideally already purchased door frame with installation instructions or a data sheet stating the opening size,
- a confirmed floor build-up, meaning the thickness of screed, underlay and floor covering,
- a plan of the underfloor heating pipes and of services in the ceiling, if there are any,
- an agreed switch position, so the electrician can run cables before the partition is closed,
- clear access to the partition location and space to store long profiles and boards,
- in a block of flats, consent from the freeholder or managing agent and agreed hours when drilling into the ceiling is allowed.
The work takes longer when the frame type or opening direction changes during installation. Unfinished electrical work in the partition also causes delays. So does a frame delivered only after boarding, which then turns out to need a different opening.
Typical mistakes and how they show up later
A CW stud instead of a UA profile. Often with the explanation that it is only a light door. The frame moves slightly each time the door is slammed. After some months the frame works loose, the door drops and rubs on the floor or threshold.
Fixing only into the floor covering, screed, suspended ceiling or plasterboard. The profile has no firm support in the structure. The whole frame wobbles.
Too few anchors or anchors unsuitable for the substrate. Ceilings are not always solid concrete. Hollow-core planks, beam-and-block floors with clay or concrete infill blocks and aerated concrete units need different anchors from solid concrete. An ordinary expansion anchor holds at first, but vibration from the door gradually loosens it.
A UA profile cut tight with no tolerance. The profile wedges between floor and ceiling. When the ceiling moves, it can bow and distort the opening.
An opening without fitting tolerance or measured from the bare floor. The frame cannot be fitted. In other cases, once the floor is laid the leaf rubs on the floor and has to be trimmed, or a large gap is left under the door.
Changing the frame type after the frame has been built. A different frame needs a different opening. The frame has to be altered, sometimes with boards removed.
A board joint in line with the edge of the opening. A crack appears above the corner of the door. It returns after filling and repainting.
A door frame forced into the opening. The frame is put under stress and the door frame can twist. The door then does not close evenly.
Most of these mistakes are not visible straight after installation. They show up after a few months of use. Putting them right usually means taking part of the partition apart.
How to check the finished reinforcement
The work is best checked before boarding, while the structure is still visible. Agree with the installer to be told when the frame is complete. Alternatively, ask for photos of it. At handover, look for the following:
- whether there really are UA profiles on both sides of the opening, recognisable by the thicker steel,
- whether the profiles are fixed to the structural floor and ceiling through connecting angles,
- whether the side profiles are plumb and the distance between them is the same at top and bottom,
- whether the door head is level and firmly connected to the side profiles,
- whether the opening height matches the finished floor level and the chosen frame,
- whether the frame stays still when pushed by hand,
- whether, after boarding, no board joint lines up with the edge of the opening,
- whether the screw heads are sunk and the edges around the opening are filled without cracks,
- whether the fitted door opens easily, does not swing on its own and closes evenly.
If you are building the partition yourself
Anyone who has already built a plasterboard partition can manage a door frame as well. The process is the same as in the step-by-step section above. With underfloor heating, a floating floor, a timber ceiling or in a loft room, it is more sensible to leave the work to a professional. Do not connect any electrics in the partition yourself. Cables and back boxes are a job for a qualified electrician. All new electrical work should be designed, installed and certified to BS 7671:2018+A4:2026, the current IET Wiring Regulations, and a new circuit is notifiable under Part P, so use an electrician registered with a competent person scheme (e.g. NICEIC or NAPIT) or notify building control before you start.
In addition to standard plasterboard tools, you need UA profiles of the same width as the CW studs in the partition, system connecting angles and anchors suitable for the floor and ceiling. You also need screws for heavier gauge steel and tin snips or a hacksaw. Points to watch:
- take the opening size from the instructions for the specific frame and measure the height from the finished floor level,
- before drilling, check with a detector or from drawings that no services run at the fixing points,
- find out what the ceiling is made of and choose anchors accordingly,
- transfer the opening position from floor to ceiling with a plumb line or laser, not by eye,
- do not cut the UA profile tight, but with the tolerance given by the system,
- fit the door frame according to its manufacturer's instructions and do not force it into the opening.
Frequently asked questions
The guide price is roughly €61.00 per piece, meaning per door opening. Expect to pay more for retrofitting reinforcement in a boarded partition, in a high room, where fixing is complicated or for heavy and concealed doors. Check whether the price also includes boarding and fitting the frame.
Some systems allow CW studs, usually doubled or reinforced with timber, only for light leaves and normal partition heights. In practice a limit of around 25 kg leaf weight is often quoted, but the system guide is what counts. For solid, heavier, taller, flush or concealed doors, a UA profile is used.
Yes. The boards around the opening have to be removed, the profiles replaced or supplemented, and the partition reboarded and jointed. That is why it is better to plan for the door from the start.
The width of the UA profile is chosen to match the width of the other studs in the partition. The whole frame is then in one plane and the boards sit flat. The specific type and fixing method are set by the guide for the system used for the partition.
Never to the plasterboard alone, as it cannot withstand long-term loading. A steel frame is screwed into the UA profiles. A timber lining is fixed with expanding foam according to the manufacturer's instructions and bears against the rigid UA profile frame.
No, but its exact height must be known. The frame is fixed into the structural floor and the opening is sized so that, once the screed and floor covering are laid, it suits the door frame. If the floor build-up changes later, the door may rub on the floor or leave too large a gap underneath.
Related work
How a plasterboard curtain pocket or LED recess is built, what to sort out before work starts and what to check when the job is handed over.
How a niche or built-in shelf is made in a plasterboard wall, what decides how much it can hold, and what to watch for in bathrooms and with lighting.
How holes for downlights, speakers and boxes are marked out and cut in plasterboard, what to watch out for and how to check the finished work.
What do stud walls, wall linings and suspended ceilings cost per m² in 2026? Labour price list for plasterboard work and a quick estimate in NUMIQ.
How a single layer plasterboard partition is built, when it is enough, what makes the job harder and how to check the finished wall.
How a flat gypsum board ceiling or suspended ceiling is installed, which boards to choose, what makes the job harder and how to check the result.
Blog
Price the whole project, not just one job
Choose items from all trades and NUMIQ turns them into a quote for your own project or your customer's project.