Price the work from the price list
Enter quantities and the price recalculates instantly. You can adjust these rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
| Roofs and coverings | ||||
| Install vapour barrier | m² | 2,00 € | - | |
| Timber roof truss installation (load-bearing structure) | m² | - | ||
| Install battening for tiled roof | m² | - | ||
| Install counter-battening | m² | 2,40 € | - | |
| Cladding facade - standing seam | m² | 14,03 € | - | |
| Lock seam / standing seam metal roof covering | m² | 10,02 € | - | |
| Install PVC waterproofing membrane (flat roof) | m² | - | ||
| Spark test PVC membrane (flat roof) | m² | - | ||
| Lay ceramic/concrete tile covering | m² | 20,05 € | - | |
What a vapour barrier does and where it goes
Every home produces a lot of water vapour from cooking, showering, drying laundry and simply breathing. Warm, moist air naturally pushes outwards. If it gets into the insulation and cools down there, it turns into water. Wet insulation works poorly, rafters and joists take on moisture, mould appears, and plasterboard and metal profiles can be damaged too.
One basic rule applies: the vapour barrier always goes on the warm side of the insulation, facing the room. It never goes between the insulation and the outside, because there it would trap moisture inside the structure.
In practice there are two situations:
- Vapour barrier in the roof build-up: the membrane is laid under the rafters, or under the insulation between the rafters, in the sloping parts of a loft room and connects to the other roof layers
- Vapour barrier in a plasterboard ceiling: the membrane sits above the plasterboard, below the insulation of the ceiling or loft floor
In a plasterboard ceiling, the layers from the room upwards are usually: plasterboard, supporting profiles, vapour barrier, insulation and finally the ceiling or roof structure. In loft rooms the two often meet. A flat ceiling runs into the sloping sections, and that transition has to stay continuous.
Vapour barrier, vapour control layer or smart membrane
People tend to call every membrane a vapour barrier, but there are real differences:
- Standard vapour barrier (polyethylene or with a reflective aluminium layer) stops almost all vapour and suits common insulated build-ups
- Vapour control layer (sometimes called a vapour retarder) only slows vapour down and lets the structure dry out in a controlled way, chosen for vapour-open build-ups
- Smart membrane changes its permeability with humidity: in winter it protects the insulation, in summer it lets the structure dry towards the inside; it is often used in loft rooms and when renovating older houses
Which type is right depends on the whole build-up: what roofing membrane is used, what insulation, and whether the roof is ventilated. Thermal performance and condensation risk are covered by local building regulations and the relevant EN standards. If you are unsure, have the build-up assessed by a designer or an experienced roofer. With reflective membranes, follow the manufacturer's instructions on orientation; usually the shiny side faces the room.
The system accessories matter just as much as the membrane: adhesive tapes for joints, a permanently flexible sealant for connections to masonry, and grommets or collars for cables, pipes and light fittings. The membrane and tapes should come from the same manufacturer so they reliably stick together.
How the job is done step by step
- Check the substrate: it must be dry, clean and free of sharp edges that could tear the membrane.
- Fit the insulation without gaps so no cold bridges form.
- Plan the runs of membrane so there are as few joints as possible.
- Lay the membrane with the correct side facing the room, loosely rather than pulled tight, and staple it as you go.
- Overlap the strips, usually by roughly 10 cm or as the manufacturer specifies, and tape every joint with system tape.
- Seal the membrane around the edges to walls, gables and knee walls with sealant and press it in place with a batten or profile.
- Seal around the chimney, pipes and cables with collars or tape.
- Inspect everything before covering it, and only then fit the profiles and plasterboard.
A service void works well in practice. Battens or supporting profiles are fixed below the membrane and the plasterboard hangs beneath them. Electrical cables and boxes for lights then run in this gap and never need to pierce the membrane. If other roof work is going on, such as counter battens or flashing details, it pays to coordinate it so the finished membrane is not damaged.
Electrical work in the ceiling must be done by a qualified electrician. For larger building alterations, check with your local building authority what the building regulations require. In a block of flats, agree the work in advance with the building management or owners' association.
What makes the job easier or harder
The effort, and therefore the cost, depends mostly on how many details have to be solved, not on the area itself. A flat ceiling in a new build with a regular floor plan and few penetrations is the simplest case. More work comes with:
- Loft rooms combining a flat ceiling with sloping sections, where the membrane must run smoothly between the planes
- Many downlights, ventilation outlets or speakers in the ceiling
- Roof windows, a chimney and knee walls that the membrane has to be shaped and sealed around
- Renovations with old, uneven masonry, where the edge connection is harder to seal
- Smart membranes and higher-quality system accessories
- Work at height under the ridge that needs scaffolding
Tapes and sealants have a temperature range. In frost or on a dusty surface they do not stick, which is why work in an unheated loft is sometimes postponed in winter.
Typical mistakes when fitting a vapour barrier
- Membrane on the wrong side. The most serious mistake: moisture then gets trapped right inside the structure.
- Overlaps without tape. Simply overlapping the strips does not seal, even if it looks as though it does.
- Cheap general-purpose tape. It peels off over time and the joint stops sealing.
- No connection to the masonry. A membrane just laid against the wall leaves a continuous gap around the edge.
- Punctured membrane. It is easily torn or drilled through while fitting profiles, and nobody repairs it.
- Holes for lights cut afterwards. It often happens that holes are cut into a finished ceiling and nobody seals the membrane around them.
- Breaks in corners and at the transition to slopes. These are the spots most often underestimated.
The consequences rarely show straight away. Damp patches, mould in corners or higher heating bills appear only after a few seasons, when the ceiling has long been closed up and a repair means taking it apart.
Checking the work before it is covered
The vapour barrier has to be inspected before plasterboard or cladding goes over it. After that you can no longer see it. When you check the work, look for these points:
- The membrane faces the room on the correct side according to the manufacturer's instructions
- All strips overlap and every joint is fully taped without creases or lifting edges
- The membrane is sealed to walls and gables around the whole perimeter with sealant or tape
- The transition between the flat ceiling and the slope is continuous
- The chimney, pipes and cables have collars or are carefully taped
- There are no holes, tears or punctures from staples and screws
- The tapes and sealants are from the same system as the membrane
- On more demanding projects, airtightness was confirmed with a blower door test
Frequently asked questions
Always on the warm side of the insulation, facing the heated room. With reflective membranes, follow the manufacturer's instructions; the shiny side usually faces inwards.
Yes, if the ceiling separates a heated room from a colder space, such as an unheated loft or roof void. A ceiling between two heated floors usually does not need one.
Yes, this is often done when a ceiling or loft is insulated later. It is wise to assess the existing build-up first. In older houses a smart membrane is often chosen because it copes better with moisture already in the structure.
They can, but every penetration must be sealed with a collar or tape. It is simpler to create a service void below the membrane and run the services there, so the membrane never needs to be pierced.
A vapour barrier stops almost all water vapour, while a vapour control layer only slows it down and lets the build-up dry out. Which one to choose depends on the whole roof or ceiling build-up.
Related work
Price the whole project, not just one job
In the building work price list you pick items from every trade, and NUMIQ turns them into a client-ready quote.