Building work price list: Draining a Heating System
Enter quantities and the price recalculates instantly. You can adjust the rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
Heating works cost | ||||
| Drain heating system | pcs | €55.00 / pcs | pcs | enter quantity- |
| Remove & re-install radiator (complete) | pcs | €180.00 / pcs | pcs | enter quantity- |
| Remove gas / electric boiler | pcs | €110.00 / pcs | pcs | enter quantity- |
| Remove hot water cylinder | pcs | €109.00 / pcs | pcs | enter quantity- |
| Install & connect panel radiator | pcs | pcs | - | |
| Install bathroom towel radiator | pcs | €120.00 / pcs | pcs | enter quantity- |
| Lay underfloor heating insulation board | m² | €3.50 / m² | m² | enter quantity- |
| Underfloor heating pipe installation | m | €4.50 / m | m | enter quantity- |
| Install underfloor heating manifold | pcs | pcs | - | |
| Install gas condensing boiler | pcs | pcs | - | |
| Installation of air-to-water heat pump | pc | €950.00 / pc | pc | enter quantity- |
| Earth / bond heating system | pcs | pcs | - | |
| Replace thermostatic radiator valve (TRV) | pcs | €19.00 / pcs | pcs | enter quantity- |
| Replace return valve | pcs | €19.00 / pcs | pcs | enter quantity- |
| Install circulation pump | pcs | pcs | - | |
| Pre-wire for smart thermostat connection | pcs | pcs | - | |
| Install & connect low-loss header | pcs | pcs | - | |
| Install expansion vessel | pcs | €54.00 / pcs | pcs | enter quantity- |
| Install recirculation pipework | pcs | pcs | - | |
| Install domestic hot water (DHW) / recirculation pump | pcs | pcs | - | |
| Thread pipework | pcs | €55.00 / pcs | pcs | enter quantity- |
| Flame weld metal pipework | pcs | €20.00 / pcs | pcs | enter quantity- |
| Pressure test heating system | hr | €130.00 / hr | hr | enter quantity- |
| Fill, bleed & balance heating system | hr | €70.00 / hr | hr | enter quantity- |
| Pipework for radiators | lm | €9.00 / lm | lm | enter quantity- |
| Flush & clean existing heating system | hr | €50.00 / hr | hr | enter quantity- |
| Pipe freezing | pcs | €50.00 / pcs | pcs | enter quantity- |
| Cap off radiator | pcs | €65.00 / pcs | pcs | enter quantity- |
| Fill heating system | pcs | pcs | - | |
| Chase heating pipes in floor | lm | €24.00 / lm | lm | enter quantity- |
| Concrete-in heating pipes in floor | lm | €6.50 / lm | lm | enter quantity- |
| Install radiator bracket | pcs | €17.00 / pcs | pcs | enter quantity- |
| Install thermostatic radiator valve (TRV) & head | pcs | €19.00 / pcs | pcs | enter quantity- |
| Pressurise & bleed radiator | pcs | €12.00 / pcs | pcs | enter quantity- |
What draining a heating system involves and when it makes sense
When a system is drained, all the water runs out of the radiators, pipework and boiler. This is done when part of the system needs replacing or repairing and the water would get in the way. Typical examples are a new radiator, a leaking valve, a boiler replacement or a bathroom refit. Another reason is a holiday home or empty house that will not be heated over winter and is at risk of frost.
A common question is whether the heating should be drained every year before winter. It should not. Water that has circulated in the system for years has lost its oxygen, and the limescale has already dropped out of it. It is therefore kinder to the pipes and boiler than fresh mains water. Each refill brings new oxygen and more limescale into the system, which encourages corrosion and sludge. Unnecessary draining does more harm than good.
Draining makes sense mainly in these cases:
- replacing or moving a radiator that cannot be isolated on its own valves,
- repairing or replacing pipework, valves, the pump or the boiler,
- flushing a system full of sludge, for example when an old boiler is replaced with a new one,
- winter shutdown of a property that will not be kept frost-free and could freeze.
For a single radiator there is often no need to drain the whole house. If the radiator has a thermostatic radiator valve and a lockshield valve, the heating engineer closes both and drains only that radiator. More on this is covered under radiator removal and installation.
Draining itself is not complicated. Refilling, bleeding and setting the pressure need more care.
What to decide and find out in advance
- The whole system or only part of it: ask the heating engineer whether just the radiator or the section being worked on can be isolated. This saves time and less fresh water enters the system.
- What the system is filled with: plain water, treated water with inhibitor or an antifreeze mix. Antifreeze must not be poured down the drain. It has to be collected and taken for disposal, and a new mix of the same type prepared.
- What it will be refilled with: the boiler manufacturer often specifies the water quality and inhibitor to use. It is best to have this ready before the system is drained.
- The scope of the job: agree whether the engineer will only drain the system, or also refill it, bleed it, check the expansion vessel and recommission it after the work.
- Timing: work outside the heating season is easiest. In winter, expect the house to be without heating for several hours or even days.
How the heating engineer approaches different systems
Radiator central heating
The water is let out through the drain-off cock at the lowest point of the system. It is usually near the boiler, at the bottom of a pipe run or under the lowest radiator. A hose is fitted to the drain-off cock and run to a drain or outside. The bleed valves on the radiators are then opened one by one, starting on the top floor. Air enters through them so the water can run out. On a sealed system the filling loop must be closed first. On an older open-vented system the water supply to the feed and expansion tank in the loft is turned off or the float valve tied up. Otherwise the system keeps refilling itself.
Underfloor heating
Underfloor heating has long loops of pipe lying flat under the floor. Gravity alone will not empty them. If the underfloor heating is being drained because of frost risk, the engineer blows out each circuit at the manifold with compressed air or flushes it. Otherwise the underfloor circuits are usually just closed at the manifold and left full.
Flat in a block with communal heating
If the flat is connected to a communal heating system for the building, the water is not drained by the occupant. The risers are part of the shared pipework, so draining and refilling are arranged by the managing agent or the management company. Without their agreement a whole section of the building could be left without heat. Before replacing a radiator, contact the managing agent first and agree a date with them.
How the work goes, step by step
- Survey: the heating engineer finds the lowest point of the system, checks the condition of the valves and what the system is filled with, and decides whether draining part of it is enough.
- Shutdown: the boiler is switched off and the water left to cool. A solid fuel boiler must be completely out, as it must never run without water. The water supply to the system is also shut off.
- Draining: the water runs out through a hose from the lowest point. Antifreeze is collected in containers. Air is let in through the bleed valves.
- Thorough emptying for a winter shutdown: as well as the radiators and low pipe bends, the boiler itself and its heat exchanger are drained (many boilers have their own drain valve), together with the hot water cylinder if there is one, following the manufacturer's instructions. Underfloor circuits are blown out.
- Repair or replacement: the radiator, valve, pump or boiler is replaced on the empty system.
- Refilling: the engineer closes the drain-off cocks, checks the expansion vessel pressure, refills the system slowly and bleeds it as it fills.
- Recommissioning: the pressure is set to the boiler manufacturer's figure, the boiler is switched on, the system is brought up to temperature, bled again and all joints are checked.
What affects the price
The guide labour price is €55.00 per job. This applies to a straightforward system with an easily accessible drain-off cock, working valves and a single storey. The final figure may vary depending on what the engineer finds on site:
- Size of the system: many radiators or several floors mean more bleed valves, longer draining and longer refilling. In a larger house the job can take up to twice the usual time.
- Radiators combined with underfloor heating: the circuits at the manifold must be closed or, for a winter shutdown, blown out with compressed air. This is a separate and more labour-intensive part.
- Condition of the valves: seized or leaking valves can fail when opened. Replacing them is charged separately, including materials.
- No drain-off cock: a radiator union has to be loosened and the water caught in containers, which is slower and needs more care.
- Dirty water: sludge and deposits block the drain-off cocks, and the system often needs a flush, which is a separate job.
- Antifreeze: it must be collected and taken for disposal, and new antifreeze bought for the refill. This raises the cost noticeably compared with plain water.
- Winter shutdown: draining the boiler and hot water cylinder and blowing out the circuits adds work compared with ordinary draining before a repair.
- Refilling and recommissioning: if included in the order, allow for extra time and possibly the cost of inhibitor or treated water.
What makes the job easier and what slows it down
- Clear access to the boiler and drain-off cock: a tidy airing cupboard, utility room or cellar saves time. If the drain-off cock is behind shelving or furniture, the engineer first has to get to it.
- Access to the radiators: move furniture, curtains and items on windowsills so the bleed valves can be opened and drips caught. If radiators are hidden behind covers, these need to come off - more on this under radiator boxing in.
- Where the water goes: it helps to know where the nearest drain, gully or suitable spot outside is for the hose.
- Boiler documents: the boiler manual and information about what the system is filled with save searching and guesswork.
- A cooled system: switching the boiler off a few hours before the engineer arrives avoids waiting for the water to cool.
- Materials ready: if a radiator or valve is being replaced, the new part should be on site before draining, so the system is not left empty for longer than necessary.
Common mistakes and how they show up later
Draining a hot system. Hot water can scald. An ordinary garden hose softens, can slip off the drain-off cock and flood the floor.
Forgetting the water supply. Water keeps running and the system never seems to empty.
Water left at the lowest points. In a winter shutdown, a small amount of water in a radiator, a pipe bend, the boiler heat exchanger or the hot water cylinder is enough for frost to split it. The damage only shows on refilling, when water starts leaking from the cracked part.
Underfloor heating drained by gravity only. Water stays in the flat loops and frost can damage the pipes in the floor. The repair then means breaking up the floor and screeding the underfloor heating pipes again. Wet underfloor heating should be installed and pressure-tested to BS EN 1264-4 before the screed is laid.
Forcing old valves. A seized valve can easily snap. It is better to have a spare part or a heating engineer to hand.
Antifreeze down the drain or plain water instead of it. Antifreeze does not belong in the drain. If the system is refilled with plain water only, an unheated property loses its frost protection. Mixing different types of antifreeze can cause deposits.
Poor bleeding. Air collects at the top of the radiators, so they are cold at the top and only warm at the bottom. The system gurgles and the pump suffers.
Wrong pressure. With low pressure the boiler shows a fault, with high pressure the pressure relief valve discharges.
Expansion vessel not checked. If the vessel pressure is low, the system pressure swings widely as it heats and cools, the pressure relief valve drips and the boiler shows faults.
How to check the finished work
After refilling and switching the heating on, it is worth watching the system for a few hours and checking the pressure again over the next few days. Air is released gradually, so bleeding the radiators a second time is normal.
- the pressure gauge reads within the boiler manufacturer's range and does not drop once warm,
- the boiler shows no fault and the pump runs quietly,
- all radiators heat evenly across their whole surface,
- there is no gurgling or hissing in the system,
- joints, valves and the drain-off cock are dry,
- the pressure relief valve is not dripping,
- with underfloor heating, all circuits at the manifold are open and the flow meters show flow,
- after a winter shutdown, the radiators, circuits, boiler and hot water cylinder are empty, and the engineer has shown which joints and cocks were left open,
- where parts were replaced, the engineer has stated what was changed and what pressure the system was filled to.
DIY guide: draining radiator central heating in a house
A competent DIYer can drain a simple radiator system. Do not touch the gas supply or the boiler's electrics - gas work must be done by a Gas Safe registered engineer and electrical work by a qualified electrician. If you smell gas, call the free 24-hour National Gas Emergency Service on 0800 111 999 (0800 002 001 in Northern Ireland). If unsure where the lowest point is or what each valve does, call a heating engineer. Underfloor heating for a winter shutdown and systems with antifreeze are better left to a professional. For wider context, see the overview of heating work.
- Switch the boiler off at the controls or the fused spur and wait until the radiators are lukewarm to the touch.
- Close the filling loop on a sealed system, or turn off the supply to the feed and expansion tank on an open-vented system.
- Get a hose, buckets, old towels and a radiator bleed key ready.
- Fit the hose to the drain-off cock at the lowest point and run the end to a drain or outside, lower than the drain-off cock.
- Open the drain-off cock.
- Open the radiator bleed valves one by one, starting on the top floor.
- Wait until the water stops running, and check the lowest radiators where water may have stayed.
- For a winter shutdown, also loosen the unions on the lowest radiators, drain the boiler and hot water cylinder according to their instructions, and leave the system open so no water remains anywhere.
- Before refilling, close all valves and drain-off cocks and check the expansion vessel pressure according to the boiler manual.
- Refill slowly, ideally adding inhibitor or using treated water as recommended by the boiler manufacturer, and bleed the radiators as it fills, from the lowest to the highest.
- Top up the pressure to the manufacturer's figure, usually around 1 to 1.5 bar cold for a sealed system in a house.
- Switch the boiler on, let the system heat up, bleed it again and check the pressure.
Frequently asked questions
A standard drain-down costs around €55.00 per job. Expect to pay more for a large or combined system, antifreeze or faulty valves. Agree refilling and recommissioning separately in the quote.
In a smaller house with radiators the water usually drains in under an hour. Cooling down, refilling and bleeding take longer. Larger and combined systems can take several hours.
No. If the house is heated or kept frost-free, the water should stay in the system. It is drained only for repairs, replacing parts or a winter shutdown without frost protection.
Not in a flat with communal heating. Draining the riser is the responsibility of the managing agent or management company. They often set the date as well, usually outside the heating season.
Ideally with the water the boiler manufacturer recommends, usually with a corrosion inhibitor added. In hard water areas treated or softened water is often used. If the system contained antifreeze, use the same type in the correct ratio, not plain water.
Most often there is air in it or a valve has been left closed. If the radiator is cold at the top, bleeding will help. If it is cold at the bottom, or still not heating after bleeding and checking the valves, it may be blocked with sludge or the system may be poorly balanced, and a heating engineer should be called.
Related work
How a radiator is taken off the wall and refitted, what makes the job harder, what to consider in a flat and how to check the finished work.
How a radiator is boxed in with plasterboard, timber, MDF or metal, what to watch with airflow and valves, and how to check the finished cover.
How underfloor heating pipes are covered with screed, which screed to choose, why the pressure test matters and how to heat the floor up for the first time.
How a floor chase for heating pipes is cut, what makes the job harder, what to watch for in a block of flats and how to check the finished work.
How radiator valves are fitted and replaced, which valve types to choose, common mistakes to avoid and how to check the finished work.
How a heating system is filled, what pressure to set, how to bleed radiators and what to check once the work is finished.
Blog
Price the whole project, not just one job
Choose items from all trades and NUMIQ turns them into a quote for your own project or your customer's project.