Price the work from the price list
Enter quantities and the price recalculates instantly. You can adjust these rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
| Heating works | ||||
| Pre-wire for smart thermostat connection | pcs | - | ||
| Remove & re-install radiator (complete) | pcs | 170,40 € | - | |
| Remove gas / electric boiler | pcs | 102,23 € | - | |
| Remove hot water cylinder | pcs | 109,25 € | - | |
| Install & connect panel radiator | pcs | - | ||
| Install bathroom towel radiator | pcs | 50,10 € | - | |
| Lay underfloor heating insulation board | m² | 3,50 € | - | |
| Underfloor heating pipe installation | m | 6,50 € | - | |
| Install underfloor heating manifold | pcs | - | ||
| Install gas condensing boiler | pcs | - | ||
| Install thermostatic radiator valve (TRV) & head | pcs | 19,04 € | - | |
| Earth / bond heating system | pcs | - | ||
| Replace thermostatic radiator valve (TRV) | pcs | 19,04 € | - | |
| Replace return valve | pcs | 19,04 € | - | |
| Install circulation pump | pcs | - | ||
| Install & connect low-loss header | pcs | - | ||
| Install expansion vessel | pcs | 54,12 € | - | |
| Install recirculation pipework | pcs | - | ||
| Install domestic hot water (DHW) / recirculation pump | pcs | - | ||
| Thread pipework | pcs | 10,02 € | - | |
| Flame weld metal pipework | pcs | 20,05 € | - | |
| Pressure test heating system | hr | 40,10 € | - | |
| Drain heating system | pcs | - | ||
| Fill, bleed & balance heating system | hr | 40,10 € | - | |
| Pipework for radiators | lm | 9,02 € | - | |
| Flush & clean existing heating system | hr | 45,10 € | - | |
| Pipe freezing | pcs | 34,08 € | - | |
| Cap off radiator | pcs | 65,15 € | - | |
| Fill heating system | pcs | - | ||
| Chase heating pipes in floor | lm | 24,06 € | - | |
| Concrete-in heating pipes in floor | lm | 6,50 € | - | |
| Install radiator bracket | pcs | 17,04 € | - | |
| Install radiator valves | pcs | 17,04 € | - | |
| Pressurise & bleed radiator | pcs | 14,03 € | - | |
What this job actually includes
This is not fitting the thermostat itself. It is preparing the route for it. Typically it covers:
- Choosing the thermostat position in the reference room, usually the living room
- Fitting a back box into the wall at the correct height
- Laying a flexible conduit from the back box to the boiler, heat pump or consumer unit
- Pulling through a control cable with enough cores and some slack
- Preparing a power supply for thermostats that need a separate one
- With underfloor heating, also preparing a route for the floor sensor and zone controls
- Labelling the cable ends and recording where the route runs
The conduit matters in practice. If the cable is ever damaged, or a new thermostat needs a different cable, it can be pulled out and replaced without breaking into the wall.
Where to put the thermostat
Why does the position matter so much? A thermostat only measures the temperature where it hangs, and it controls the heating for the whole home or zone based on that reading. In the wrong spot, the heating switches off too early or too late.
- On an internal wall, not an external one, which tends to be colder in winter
- Usually about 1.5 metres above the floor
- Away from radiators, fireplaces, the cooker, the television and direct sunlight
- Away from draughts near doors and windows
- Somewhere furniture or curtains will not cover it
- For Wi-Fi thermostats, somewhere with a good home network signal
In practice it often happens that the back box goes wherever there was space left, and only once the room is furnished does it turn out the thermostat is behind a wardrobe or right next to a radiator. It pays to decide the position together with your furniture layout.
How the job is done, step by step
- Confirm the heat source and the planned type of control: simple on/off switching, a communication protocol (for example OpenTherm or eBUS, depending on the boiler) or zone control.
- Check the boiler manufacturer's instructions and, if already chosen, the thermostat's: number of cores, cable type, power requirements.
- Mark the thermostat position and the route to the heat source or consumer unit.
- Chase or cut the channels, fit the back box and lay the conduit.
- Pull the cable through with slack at both ends and at least one or two spare cores.
- If a separate supply is needed, run a protected feed from the consumer unit.
- Insulate and label the cable ends and fit a blank cover over the back box.
- Record the route and core labelling, ideally with photos taken before plastering.
Work on the electrical installation, a new power circuit and anything inside the consumer unit must be done by a qualified electrician. Connection to the boiler terminals is usually done by the boiler service engineer, partly to protect the warranty. Only a qualified, registered gas engineer may work on the gas side of the boiler. If you smell gas, leave the property and call your local gas emergency number or 112.
Wired, wireless or zoned: what to prepare
Wired thermostat
This needs a cable all the way to the boiler. For simple on/off switching two cores are often enough, but thermostats that communicate with the boiler or need power require more. That is why a multi-core cable is pulled in, even if only two cores are connected today.
Wireless thermostat
The wall unit runs on batteries, but there is usually a receiver at the boiler that needs space, power and a connection to the boiler. So the preparation is not skipped entirely. It is still worth laying a cable to the back box in case you switch to a wired model later.
Zone control and underfloor heating
Each zone has its own thermostat, and the cable runs to the manifold or to a box with the control unit. The floor sensor goes into a conduit in the floor before the screed is poured, so it can be replaced if it fails. Once the floor is poured, nothing more can be added.
What makes the job easier or harder
Pre-wiring is simplest at the shell stage or during a renovation, when the walls are unplastered and the electrician is running the other circuits too. It takes more work, and therefore costs more, in a finished home, where you have to cut into plaster or tiles and then make good the surface, or run the cable in trunking.
The job also depends on the distance between thermostat and boiler, how many walls and ceilings the route crosses, the number of zones, whether a separate power supply is needed and whether there is free space in the consumer unit. In a block of flats with communal heating, check first with the building management or owners' association what control options you actually have. With your own boiler in the flat, things are simpler. If the pre-wiring is part of a larger renovation, check with your local building authority whether the overall works need approval.
Typical mistakes
- Thermostat on an external wall or next to a heat source
- A cable with exactly as many cores as needed today and nothing spare
- Cable plastered straight into the wall without conduit
- Control cable run tightly alongside mains cables over a long distance, which can cause signal interference
- Unlabelled ends and no record of the route
- Mixing up low-voltage and mains connections when the thermostat is connected
- A missing floor sensor discovered only after the screed has been poured
How to check the finished pre-wiring
- The back box is in the agreed position and at the right height
- The cable is in conduit and can still move inside it
- There is enough slack at both ends
- The number of cores matches the planned thermostat, with spares left over
- The ends are insulated and labelled, and the back box is covered
- The electrician has tested the cable for continuity
- For a new power circuit, you have the electrical installation certificate or test report
- You have photos of the route and a written record of the connections
Frequently asked questions
Yes, especially when swapping an old thermostat for a new one on the existing wiring. Often, though, it turns out a core or power supply is missing, and then you either have to cut into a finished wall or choose a wireless solution.
Not necessarily. Knowing the heat source and the type of control is enough. A multi-core cable in conduit covers most common models. If you have already chosen a thermostat, follow the manufacturer's instructions.
Connection to the boiler, power supply work and anything in the consumer unit belong to a qualified electrician and the boiler service engineer. You can help with preparatory work, such as chasing channels, if you agree it with the electrician first.
For the pre-wiring alone, usually not. Draining only comes into question if valves, actuators or other parts of the heating circuit are being changed at the same time.
If a new power circuit is installed or the consumer unit is altered, the electrician should test the work and issue a certificate. It is also useful for your insurer and when you sell the property.