Building work price list: Radiator Valve Installation
Enter quantities and the price recalculates instantly. You can adjust the rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
Heating works cost | ||||
| Remove & re-install radiator (complete) | pcs | €180.00 / pcs | pcs | enter quantity- |
| Remove gas / electric boiler | pcs | €110.00 / pcs | pcs | enter quantity- |
| Remove hot water cylinder | pcs | €109.00 / pcs | pcs | enter quantity- |
| Install & connect panel radiator | pcs | pcs | - | |
| Install bathroom towel radiator | pcs | €120.00 / pcs | pcs | enter quantity- |
| Lay underfloor heating insulation board | m² | €3.50 / m² | m² | enter quantity- |
| Underfloor heating pipe installation | m | €4.50 / m | m | enter quantity- |
| Install underfloor heating manifold | pcs | pcs | - | |
| Install gas condensing boiler | pcs | pcs | - | |
| Installation of air-to-water heat pump | pc | €950.00 / pc | pc | enter quantity- |
| Earth / bond heating system | pcs | pcs | - | |
| Replace thermostatic radiator valve (TRV) | pcs | €19.00 / pcs | pcs | enter quantity- |
| Replace return valve | pcs | €19.00 / pcs | pcs | enter quantity- |
| Install circulation pump | pcs | pcs | - | |
| Pre-wire for smart thermostat connection | pcs | pcs | - | |
| Install & connect low-loss header | pcs | pcs | - | |
| Install expansion vessel | pcs | €54.00 / pcs | pcs | enter quantity- |
| Install recirculation pipework | pcs | pcs | - | |
| Install domestic hot water (DHW) / recirculation pump | pcs | pcs | - | |
| Thread pipework | pcs | €55.00 / pcs | pcs | enter quantity- |
| Flame weld metal pipework | pcs | €20.00 / pcs | pcs | enter quantity- |
| Pressure test heating system | hr | €130.00 / hr | hr | enter quantity- |
| Drain heating system | pcs | pcs | - | |
| Fill, bleed & balance heating system | hr | €70.00 / hr | hr | enter quantity- |
| Pipework for radiators | lm | €9.00 / lm | lm | enter quantity- |
| Flush & clean existing heating system | hr | €50.00 / hr | hr | enter quantity- |
| Pipe freezing | pcs | €50.00 / pcs | pcs | enter quantity- |
| Cap off radiator | pcs | €65.00 / pcs | pcs | enter quantity- |
| Fill heating system | pcs | pcs | - | |
| Chase heating pipes in floor | lm | €24.00 / lm | lm | enter quantity- |
| Concrete-in heating pipes in floor | lm | €6.50 / lm | lm | enter quantity- |
| Install radiator bracket | pcs | €17.00 / pcs | pcs | enter quantity- |
| Install thermostatic radiator valve (TRV) & head | pcs | €19.00 / pcs | pcs | enter quantity- |
| Pressurise & bleed radiator | pcs | €12.00 / pcs | pcs | enter quantity- |
What a radiator valve does and when it is fitted
A radiator valve controls how much hot water flows into the radiator, and so how warm the room gets. New valves are needed when a heating system is installed, when a radiator is replaced, during a refurbishment, or when an old valve drips, sticks or no longer controls the heat. The job is part of wider heating work and is usually done by a heating engineer or plumber.
The work looks like a simple swap of one part for another. The result, however, depends on the right type of valve, a watertight joint, the correct flow direction, bleeding and setting up. In a block of flats with communal heating, a badly set valve can also affect the heating in neighbouring flats.
What radiator valves include
A standard radiator has two valves. On the flow side is the control valve, which sets the temperature. On the return side is the lockshield valve. It allows the radiator to be isolated and its flow rate to be adjusted.
- a thermostatic radiator valve (TRV) with a head reduces the flow automatically according to the room temperature and is now the standard choice in houses and flats,
- a manual valve is opened and closed by turning the handle and suits utility rooms or spaces where the temperature hardly changes,
- a valve with pre-setting limits the maximum flow through a particular radiator, which matters when the system is balanced,
- angled and straight versions are chosen according to whether the pipe comes out of the wall or up from the floor,
- radiators with bottom connections have a built-in valve insert, and a connection fitting is installed underneath the radiator.
The valve body is usually brass, often chrome or nickel plated. Plastic parts are used mainly on heads and caps. When choosing a valve, it must fit the existing pipework and a suitable head must be available for it.
When replacing a valve makes sense
Not every heating problem means a new radiator. Often a new valve is enough. Consider a replacement when:
- there is damp, limescale or rust staining around or under the valve,
- the radiator stays fully hot even with the head turned down to minimum,
- the radiator stays cold while the others heat up,
- the valve hisses, whistles or knocks,
- the pin under the head is stuck and cannot be freed.
A cold radiator does not always mean a faulty valve. A common cause is air in the radiator or a stuck pin that can be freed. If the radiator still does not heat up after bleeding and freeing the pin, the valve should be replaced.
It pays to combine valve replacement with other work: radiator removal and installation, decorating, new flooring or insulation work. After a building has been insulated, the whole system is often rebalanced, and valves in all rooms or flats are replaced at the same time.
What to decide before booking the work
- Thermostatic or manual valve: in living spaces a TRV makes sense. It responds on its own to sunshine through the window, cooking or more people in the room. A manual valve suits a boiler room, cellar or garage.
- Valve only, or lockshield as well: if the lockshield valve is as old as the control valve, it is worth replacing both at once. The system has to be drained anyway, and draining again later means extra work.
- Pre-setting: if the system has been or will be balanced, the new valve should have pre-setting.
- Who supplies the materials: agree whether the heating engineer supplies the valves or you buy them yourself. If you buy them, check the connection type, pipe size and whether you need angled or straight valves. The safest approach is to photograph the old valve and its connection to the pipe.
- Head: a head from a different manufacturer than the valve often needs an adaptor. It is simpler to have a matching valve and head.
- Block of flats: with communal heating, check with the managing agent whether the replacement can be done on its own, when the riser can be shut down and whether specific valve types are required in the building.
How the installation works step by step
- Shutting down and draining: the valve body cannot be replaced under pressure. In a house, the heating engineer switches off the boiler, lets the water cool and drains at least the part of the system being worked on - see draining a heating system. In a block with communal heating, the riser has to be isolated and drained. This must be approved and arranged by the managing agent or building management, so the date is agreed in advance.
- Removing the old valve: the old valve is loosened with a spanner without twisting the pipe. The pipe or radiator tail is held with a second spanner. A container and old towels go under the radiator, as water remains in the radiator and pipes.
- Cleaning and checking threads: threads and seating surfaces are cleaned of old sealant and deposits. If a thread is damaged or corroded, the new joint will not be watertight. The heating engineer then replaces the radiator tail, cuts a new thread or replaces a section of pipe. On copper pipework a damaged end is cut back and a new olive fitted.
- Fitting the new valve: threaded joints are sealed with PTFE tape or jointing compound suitable for heating systems. Some valves have a built-in seal. The valve is fitted according to the flow direction arrow. It is tightened firmly but with care, so the nut or radiator tail does not crack.
- Fitting the lockshield valve: if the lockshield is also being replaced, the same procedure applies. After fitting, the radiator must sit on its brackets without strain, and the pipework must not pull it to one side.
- Refilling and bleeding: the system is refilled and each radiator is bled until water without bubbles comes out of the bleed valve. Corrosion inhibitor is normally added when a sealed system is refilled.
- Checking the pressure: on a sealed system with its own boiler, the pressure is topped up to the value given by the boiler manufacturer, usually around 1 to 2 bar when cold. Older open-vented systems with a feed tank in the loft refill on their own. In a block with communal heating, the pressure is handled by the managing agent or their engineer.
- Leak test: the joints are left under pressure and checked again once the water is hot. Heat expands the joint, so a leak often only shows after warming up.
- Head and setting: the thermostatic head is fitted last, usually in the fully open position. If the valve has pre-setting, it is set according to the balancing calculation or the heating engineer's recommendation.
What affects the price
The guide labour price is per piece. It applies to a like-for-like swap with good access and sound pipework, where the new valve fits the existing connection. Firms interpret a "piece" differently: some mean one valve, others a pair of valves for one radiator. Always check what exactly the price per piece covers.
- Condition of the pipework: old steel pipe that cracks when loosened or has rusted threads means a new tail, a new thread or a new section of pipe. This can make the work on one valve take several times longer.
- Connection type: if the new valve has a different spacing or connection, the pipework must be altered. That is separate, additional work.
- Access to the radiator: a radiator in a narrow recess, behind furniture or behind radiator boxing takes longer. If the radiator has to be taken off its brackets, the job takes noticeably longer.
- Draining the system: draining, refilling and bleeding often take longer than the valve swap itself. In a block of flats, isolating the riser is added to that.
- Number of valves: replacing valves in several rooms at once usually works out cheaper per piece, as the system is drained and refilled only once. A single valve is usually the most expensive per piece.
- Balancing: setting the pre-setting on several radiators according to a calculation adds extra time.
- Materials: the labour price usually does not include the valve, lockshield or head. A TRV with pre-setting and a good-quality head costs more than a simple manual valve.
When comparing quotes, ask whether draining and refilling, bleeding and setting the pre-setting are included in the price or charged separately.
What makes the job easier and what slows it down
Much of the delay comes from organisation, not the work itself. It helps the heating engineer when:
- neighbours in a block of flats know about the riser shutdown in advance,
- the area around the radiator is clear and furniture and curtains have been moved,
- the floor under the radiator is covered,
- the valves, lockshields and heads are on site before the engineer arrives,
- in a house, there is clear access to the boiler, the drain-off cock and the pressure gauge,
- you know where the water from the system can be drained, for example to an outside drain,
- the boiler documents and any balancing records are to hand.
The job is delayed when it turns out on site that the purchased valve does not fit, or when heavy furniture has to be moved during the work.
Typical mistakes and how they show up later
- poor thread sealing: either too little or unsuitable material. The joint expands each time it heats up and contracts as it cools. Weak sealing does not withstand this for long, and after a few weeks a stain appears on the floor or wall,
- valve fitted against the arrow: it then hums or knocks and thermostatic control does not work properly,
- overtightening: damages the nut or the radiator thread. A cracked nut may only leak under pressure or once hot,
- skipped bleeding: the top of the radiator stays cold and the system gurgles,
- ignored balancing: radiators near the boiler get too hot while distant ones never warm up properly,
- badly positioned head: for example covered by a curtain or pointing upwards above a hot pipe. The sensor measures a different temperature from the room, and the room stays cooler than the setting,
- wrong valve type: the original head cannot be bought for it, or it has no pre-setting in a building that has been balanced. The problem shows up at the next change to the heating.
In flats with communal heating and individual heat metering, inform the managing agent of the replacement so that billing is not affected and the valve settings match the other flats.
How to check the finished work
At handover, go through these points with the heating engineer:
- the joints are dry with hot water and after several hours of operation - wiping them with a dry paper towel helps,
- the valve is fitted according to the flow arrow,
- the radiator sits level on its brackets and the pipework does not pull it to one side,
- the radiator heats up across its whole surface, with no cold top section,
- the head responds - when turned to minimum, the radiator gradually cools,
- the head is not covered and points into the room, not upwards,
- the valve pre-settings are recorded and you know the values,
- the pressure on the boiler gauge is within the range given by the manufacturer,
- the area around the radiator is clean and free of water marks,
- in a block of flats, the riser has been refilled and the managing agent knows the work is finished.
It is worth checking the joints again after a few days of heating. If a drip appears, contact the heating engineer straight away, before the water damages the floor or wall.
DIY guide: replacing a thermostatic head and bleeding
Leave replacing the valve body to a heating engineer, especially in a block of flats. You can, however, safely replace the thermostatic head, which fits onto the valve without draining, and bleed the radiator afterwards. The water in the radiator can be hot, so it is sensible to bleed when the radiator is lukewarm.
- Identify the valve type and its connection, and if necessary buy a head with an adaptor to suit the valve manufacturer.
- Turn the old head to its highest setting.
- Loosen the nut or locking ring and pull the head off.
- Check that the valve pin springs back when pressed, and if it is stuck, free it carefully.
- Set the new head to its highest setting, fit it and tighten by hand.
- In a house with its own boiler, switch off the pump or the whole boiler and wait a while for air to collect at the top of the radiator. In a block with communal heating, the pump is not switched off and bleeding is done while the system runs.
- Place a cloth and a small container under the bleed valve.
- Open the bleed valve with a radiator key and leave it open until water without bubbles comes out.
- Close the bleed valve, switch the pump back on and, in a house with its own boiler, check the pressure on the gauge.
- Set the head to the required setting and after a few hours check that the radiator heats evenly.
If the pressure drops significantly after bleeding and you cannot safely top it up, or if water leaks around the valve pin, call a heating engineer.
Frequently asked questions
As a guide, per piece for a like-for-like swap with good access and sound pipework. Corroded pipework, altered connections, poor access to the radiator and draining a riser all increase the price. The valve, lockshield and head are usually paid for separately.
Swapping one valve with good access usually takes half an hour to an hour. Cooling down, draining, refilling and bleeding the system have to be added. Replacing the valves on one radiator in a house therefore usually takes 2 to 3 hours. In a block of flats, the time depends mainly on isolating the riser.
Not always the whole system, but at least the part where the valve is. In a house it is often possible to isolate just one branch, while in a block with communal heating the riser is drained. A thermostatic head on its own can be replaced without draining.
Yes, but the work is harder and takes longer, because the system has to cool down and then be refilled and bled. In a block of flats it also means cold radiators for neighbours for a few hours. If the condition of the valve allows, it is more convenient to wait for the summer.
When one valve is replaced, it is usually enough to set it similarly to the others. When all valves are replaced, after insulation work or when the boiler is replaced, balancing is recommended so that all rooms heat evenly and the pump does not work harder than necessary.
Only if the valve is thermostatic, meaning it is designed to take a head. A standard manual valve will not accept a head and has to be replaced. With thermostatic valves from other manufacturers, an adaptor often helps.
The body of a good-quality brass valve typically lasts 15 to 20 years, often longer. The thermostatic head sometimes needs replacing sooner. Much depends on the water quality in the system and on how the valve is used. Before each heating season, it is worth checking that it does not drip and that the pin under the head is not stuck.
Related work
When and how to drain a central heating system, what to watch for with radiators and underfloor heating, and how to refill and bleed it.
How a radiator is taken off the wall and refitted, what makes the job harder, what to consider in a flat and how to check the finished work.
How a radiator is boxed in with plasterboard, timber, MDF or metal, what to watch with airflow and valves, and how to check the finished cover.
How underfloor heating pipes are covered with screed, which screed to choose, why the pressure test matters and how to heat the floor up for the first time.
How a floor chase for heating pipes is cut, what makes the job harder, what to watch for in a block of flats and how to check the finished work.
How a heating system is filled, what pressure to set, how to bleed radiators and what to check once the work is finished.