Building work price list: Radiator Removal and Installation
Enter quantities and the price recalculates instantly. You can adjust the rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
| Heating works | ||||
| Remove & re-install radiator (complete) | pcs | 180,00 € / pcs | pcs | enter quantity- |
| Remove gas / electric boiler | pcs | 110,00 € / pcs | pcs | enter quantity- |
| Remove hot water cylinder | pcs | 109,00 € / pcs | pcs | enter quantity- |
| Install & connect panel radiator | pcs | pcs | - | |
| Install bathroom towel radiator | pcs | 120,00 € / pcs | pcs | enter quantity- |
| Lay underfloor heating insulation board | m² | 3,50 € / m² | m² | enter quantity- |
| Underfloor heating pipe installation | m | 4,50 € / m | m | enter quantity- |
| Install underfloor heating manifold | pcs | pcs | - | |
| Install gas condensing boiler | pcs | pcs | - | |
| Earth / bond heating system | pcs | pcs | - | |
| Replace thermostatic radiator valve (TRV) | pcs | 19,00 € / pcs | pcs | enter quantity- |
| Replace return valve | pcs | 19,00 € / pcs | pcs | enter quantity- |
| Install circulation pump | pcs | pcs | - | |
| Pre-wire for smart thermostat connection | pcs | pcs | - | |
| Install & connect low-loss header | pcs | pcs | - | |
| Install expansion vessel | pcs | 54,00 € / pcs | pcs | enter quantity- |
| Install recirculation pipework | pcs | pcs | - | |
| Install domestic hot water (DHW) / recirculation pump | pcs | pcs | - | |
| Thread pipework | pcs | 55,00 € / pcs | pcs | enter quantity- |
| Flame weld metal pipework | pcs | 20,00 € / pcs | pcs | enter quantity- |
| Pressure test heating system | hr | 130,00 € / hr | hr | enter quantity- |
| Drain heating system | pcs | pcs | - | |
| Fill, bleed & balance heating system | hr | 70,00 € / hr | hr | enter quantity- |
| Pipework for radiators | lm | 9,00 € / lm | lm | enter quantity- |
| Flush & clean existing heating system | hr | 50,00 € / hr | hr | enter quantity- |
| Pipe freezing | pcs | 50,00 € / pcs | pcs | enter quantity- |
| Cap off radiator | pcs | 65,00 € / pcs | pcs | enter quantity- |
| Fill heating system | pcs | pcs | - | |
| Chase heating pipes in floor | lm | 24,00 € / lm | lm | enter quantity- |
| Concrete-in heating pipes in floor | lm | 6,50 € / lm | lm | enter quantity- |
| Install radiator bracket | pcs | 17,00 € / pcs | pcs | enter quantity- |
| Install thermostatic radiator valve (TRV) & head | pcs | 19,00 € / pcs | pcs | enter quantity- |
| Pressurise & bleed radiator | pcs | 12,00 € / pcs | pcs | enter quantity- |
When it makes sense to take the radiator off
If the wall behind only needs a quick coat of paint, a long-handled radiator roller or careful masking is often enough. Full removal makes sense when the wall changes more: new plaster, a skim coat, tiles, wallpaper or internal insulation. When you replace flooring, removal helps most if the floor height changes and the pipes will need adjusting afterwards.
Removal is also the first step when you swap a radiator for a new one. This job assumes the same radiator goes back in the same place. If the type, size or connection layout changes, the work becomes more involved.
How the job is done step by step
The method depends on whether the radiator has working valves on both sides: the thermostatic valve on the flow and the lockshield valve on the return. If both close and seal properly, there is no need to drain the whole system. If they are missing or seized, at least part of the system has to be drained.
- Switch off the heating and let the radiator cool down.
- Close the thermostatic valve on the flow and the lockshield valve on the return, counting and noting the turns on the lockshield so it can be reset.
- Place a tray under the joints and lay down old towels.
- Loosen the nuts on both joints and drain the water from the radiator.
- Lift the radiator off its brackets and carry it to a safe place, with two people for larger ones.
- Fit caps or blanking nuts on the open valves.
- After the other work is finished, check the brackets, seals and threads and replace worn seals.
- Hang the radiator back, level it and reconnect the joints.
- Open the valves slowly, let the radiator fill and check for leaks.
- Bleed the radiator, check the system pressure and return the valves to their original settings.
Why does the lockshield setting matter? When the system was set up, it was used to balance how much water flows through each radiator. If someone simply closes it and then opens it fully, that radiator can take heat away from the other rooms.
What makes the job easier or harder
How demanding the job is depends mainly on what the engineer finds on site. These make the work easier:
- A panel radiator with a working thermostatic valve and lockshield
- Newer joints that loosen without much force
- Clear access and solid brackets in a sound wall
These make it harder:
- A cast iron column radiator, which is very heavy and often has corroded joints
- Seized or leaking valves that need replacing
- No isolation valves, so the system or riser has to be drained
- A change in wall or floor thickness that means extending pipes or moving brackets
- Loose wall plugs in crumbling plaster or old masonry
- Heavily contaminated system water that clogs the valves
In practice an old valve that is closed for the first time in years often stops sealing properly. It pays to expect this and replace the valve while the radiator is off anyway.
Typical mistakes and how to avoid them
- Radiator not level: it is harder to bleed and air stays trapped in one corner, so check with a spirit level before tightening the joints
- Old seals reused: the joint may hold for a few days and then start to weep, so fit new ones
- Flow and return swapped: the valve may hum or regulate poorly, and the flow direction is usually marked with an arrow on the valve
- Bleeding forgotten: the radiator heats only at the bottom or not at all, so always bleed after refilling
- Lockshield set wrongly: one room overheats while another stays cold
- Radiator too close to the wall: air circulates poorly and dust builds up behind it, the usual gap is a few centimetres from the wall and roughly a hand's width above the floor
Why is the radiator nearly always under the window? Warm air rises and meets the cold air falling from the glass. That is why it usually makes sense to put it back exactly where it was unless there is a good reason to move it.
Checking the finished work
When you take over the work, spend a few minutes with the heating running and the radiator warm:
- The radiator sits firmly on its brackets and does not move
- It is level and in the same position as before
- The joints stay dry when hot, which you can test by wiping them with a tissue
- The radiator heats evenly across its whole surface, not just at the bottom
- The thermostatic head turns freely and responds
- The lockshield is set as it was originally
- The boiler pressure is within the manufacturer's range
- In a flat, the heat cost allocator is back in place and correctly sealed
- The surroundings are dry and the wall and floor are undamaged
After a few days of use, look under the joints once more. Small weeps often only show after the first few cycles of heating up and cooling down.
Frequently asked questions
Not always. If the radiator has a working thermostatic valve and a lockshield that closes, it is enough to shut both and drain just the radiator. If the valves are missing or do not seal, the system has to be drained, or in a block of flats the riser.
Not without agreement from the building management or owners' association. It is a shared system, a mistake can flood the neighbours below, and there may be a heat cost allocator that residents are not meant to handle themselves.
As long as the work on the wall or floor takes. What matters is that the open valves are reliably capped. During the heating season, remember the room will be colder and plaster or skim coats will dry more slowly.
In most cases, yes. After years in use, old seals are compressed and hardened, and new ones are a cheap safeguard against leaks. This applies even more to cast iron radiators and old joints.
Usually there is air trapped inside. Bleed it with the heating on until water comes out of the bleed valve without bubbles. With your own boiler, check the pressure afterwards and top up if needed.
Related work
When and how to drain a central heating system, what to watch for with radiators and underfloor heating, and how to refill and bleed it.
How a radiator is boxed in with plasterboard, timber, MDF or metal, what to watch with airflow and valves, and how to check the finished cover.
How underfloor heating pipes are covered with screed, which screed to choose, why the pressure test matters and how to heat the floor up for the first time.
How a floor chase for heating pipes is cut, what makes the job harder, what to watch for in a block of flats and how to check the finished work.
How radiator valves are fitted and replaced, which valve types to choose, common mistakes to avoid and how to check the finished work.
How a heating system is filled, what pressure to set, how to bleed radiators and what to check once the work is finished.
Blog
Price the whole project, not just one job
Choose items from all trades and NUMIQ turns them into a quote for your own project or your customer's project.