Building work price list: Heated towel rail installation
Enter quantities and the price recalculates instantly. You can adjust the rates in your price list.
All prices shown exclude VAT. Labour price covers labour only. Price incl. materials adds sundry materials (adhesive, primer, sealants, fixings). Tiles, flooring, paint and sanitaryware are chosen and bought by the client and are not included.
| Item | Unit | Price / unit | Quantity | Total |
|---|---|---|---|---|
Heating works cost | ||||
| Install bathroom towel radiator | pcs | €120.00 / pcs | pcs | enter quantity- |
| Remove & re-install radiator (complete) | pcs | €180.00 / pcs | pcs | enter quantity- |
| Remove gas / electric boiler | pcs | €110.00 / pcs | pcs | enter quantity- |
| Remove hot water cylinder | pcs | €109.00 / pcs | pcs | enter quantity- |
| Install & connect panel radiator | pcs | pcs | - | |
| Lay underfloor heating insulation board | m² | €3.50 / m² | m² | enter quantity- |
| Underfloor heating pipe installation | m | €4.50 / m | m | enter quantity- |
| Install underfloor heating manifold | pcs | pcs | - | |
| Install gas condensing boiler | pcs | pcs | - | |
| Installation of air-to-water heat pump | pc | €950.00 / pc | pc | enter quantity- |
| Earth / bond heating system | pcs | pcs | - | |
| Replace thermostatic radiator valve (TRV) | pcs | €19.00 / pcs | pcs | enter quantity- |
| Replace return valve | pcs | €19.00 / pcs | pcs | enter quantity- |
| Install circulation pump | pcs | pcs | - | |
| Pre-wire for smart thermostat connection | pcs | pcs | - | |
| Install & connect low-loss header | pcs | pcs | - | |
| Install expansion vessel | pcs | €54.00 / pcs | pcs | enter quantity- |
| Install recirculation pipework | pcs | pcs | - | |
| Install domestic hot water (DHW) / recirculation pump | pcs | pcs | - | |
| Thread pipework | pcs | €55.00 / pcs | pcs | enter quantity- |
| Flame weld metal pipework | pcs | €20.00 / pcs | pcs | enter quantity- |
| Pressure test heating system | hr | €130.00 / hr | hr | enter quantity- |
| Drain heating system | pcs | pcs | - | |
| Fill, bleed & balance heating system | hr | €70.00 / hr | hr | enter quantity- |
| Pipework for radiators | lm | €9.00 / lm | lm | enter quantity- |
| Flush & clean existing heating system | hr | €50.00 / hr | hr | enter quantity- |
| Pipe freezing | pcs | €50.00 / pcs | pcs | enter quantity- |
| Cap off radiator | pcs | €65.00 / pcs | pcs | enter quantity- |
| Fill heating system | pcs | pcs | - | |
| Chase heating pipes in floor | lm | €24.00 / lm | lm | enter quantity- |
| Concrete-in heating pipes in floor | lm | €6.50 / lm | lm | enter quantity- |
| Install radiator bracket | pcs | €17.00 / pcs | pcs | enter quantity- |
| Install thermostatic radiator valve (TRV) & head | pcs | €19.00 / pcs | pcs | enter quantity- |
| Pressurise & bleed radiator | pcs | €12.00 / pcs | pcs | enter quantity- |
When a heated towel rail is fitted
- during a bathroom refurbishment, when the tiling is being replaced and the old radiator is swapped for a towel rail,
- when replacing an old radiator that is rusting, dripping or not heating,
- in a new build, often alongside underfloor heating so that towels stay dry even when the underfloor heating is off,
- when the bathroom needs background heat outside the heating season, in which case an electric heating element is fitted to the rail.
If you are simply replacing one radiator with another in the same position, see also radiator removal and installation. This article deals specifically with heated towel rails for bathrooms.
What to decide before the work
Output and size
For the same size, a towel rail often has a lower output than a panel or sectional radiator, because towels cover part of its surface. Manufacturers state output according to EN 442 at water temperatures of 75/65 °C and a room temperature of 20 °C. For example, a towel rail 800 mm high and 450 mm wide is listed at 368 W in one manufacturer's catalogue. At lower water temperatures, for instance with a heat pump or a condensing boiler, the actual output is considerably lower. When replacing a large cast iron radiator with a towel rail it is therefore worth recalculating the output, otherwise the bathroom will be colder.
Connection type
- bottom connection into the side tubes: two G½ connections at the bottom of the vertical tubes, with the centres depending on the width of the rail,
- central connection: two connections in the middle with 50 mm centres. The pipes from the wall or floor run side by side and connect through a twin valve,
- side connection: on some models, on the vertical tube with wider centres.
When replacing an old radiator, the deciding factor is where the pipes come out. If they do not match the new rail, the pipes have to be extended, moved or chased into the wall. This is the biggest difference in price.
Water only, dual fuel or electric
A dual-fuel rail is connected to the central heating and an electric heating element is screwed into one of the connections. In summer, when the boiler is off, the rail runs on electricity. Heating elements are typically 250 to 900 W. A purely electric rail is not connected to the heating, and some manufacturers state that a water-filled model must not be used on electricity alone, otherwise the warranty is void.
Valves
A central connection uses a twin angled or straight valve, a bottom connection uses two separate valves. A thermostatic head is of little use on a towel rail, because towels often cover it. On forums, professionals point out that with weak circulation a thermostatic valve with high resistance can leave the rail cold. Valve types are described in the article on fitting radiator valves, and materials are listed in the overview of heating materials.
Safety zones and electricity in the bathroom
If the rail has an electric element, its position is governed by the local wiring regulations for bathrooms. The rail must not be inside the bath or shower area or above them. Some manufacturers do not approve installation in zone 1 at all, others allow only a fixed connection without a socket in zones 1 and 2. A socket must not be directly below the rail or within its footprint. Only a qualified, licensed electrician may connect the electric element to the fixed wiring under national rules.
How the installation is carried out step by step
- Draining and isolating: when replacing a radiator, the valves are closed or the heating system is drained. The old radiator is removed and the pipes are capped.
- Setting out the position: the position is taken from the pipe outlets. For many models manufacturers recommend a clearance of at least 150 mm from the floor.
- Fixing the brackets: depending on the model, the rail hangs on three or four points. Brackets are fixed into masonry, and into plasterboard only where there is a noggin or a load-bearing stud.
- Hanging the rail: the rail is hung, levelled with a spirit level and the distance from the wall is set.
- Electric element: if used, it is screwed into the bottom of one of the vertical tubes before the heating is connected. How the valves are connected for dual-fuel operation is set out in the manufacturer's instructions.
- Connecting to the heating: the valves are fitted, the pipes connected and the joints sealed. With a central connection, the exact 50 mm centres of the wall outlets are important.
- Filling and pressure test: the system is refilled, and the pressure and all joints are checked.
- Bleeding: the bleed valve is at the top of the rail. Bleeding is repeated after the first heat-up until only clean water comes out.
- Balancing: the rail is adjusted with the lockshield valve on the return so that it does not starve the other radiators of water, but is not cold either.
What affects the price
The guide price for labour is €120.00 per piece. The rail, valves, extra brackets and the electric element are paid for separately. The final amount is influenced by:
- pipe position: if the pipes match the new rail, installation is quick. Moving pipes and chasing pipes into the wall is a separate job,
- draining the system: in a house you drain and refill your own system, in a block of flats the riser is drained through the building manager, which is usually charged for and tied to a set date,
- the wall: tiles, plasterboard without a noggin or hollow bricks make fixing take longer,
- connection and valve type: a central connection with a twin valve is simpler, provided the pipes come out precisely,
- electric element: fitting the element itself is quick, but connecting it to the fixed wiring and any new supply is done by an electrician,
- size and weight: large rails need two people and more fixing points,
- removing the old radiator: taking away a cast iron radiator and capping redundant outlets are charged extra.
You can work out the cost of other heating work in the heating work price list.
What should be ready
- the rail has been chosen and you know its connection type, outlet centres and height,
- the heating pipes come out in the right place, ideally to the dimensions in the instructions,
- plasterboard has a noggin where the brackets will go,
- for an electric element, a supply or box is ready in the right place outside the prohibited zones,
- in a block of flats, a date for draining the riser has been agreed with the building manager,
- the tiling is finished, or it is clear that the rail will be hung after tiling.
Common mistakes and how they show up later
A low-output rail in place of a large radiator
The bathroom is colder than before, especially with low-temperature heating. A case that comes up repeatedly on forums is a towel rail in a bathroom heated by a heat pump with a water temperature of around 33 °C that stayed cold and only warmed up when the temperature was raised during frosts.
An unbalanced system
The new rail either takes water from the other radiators or, conversely, heats only at the bottom. Professionals on forums advise balancing the flow rates with the lockshield valves first, and only then changing the rail or the pipes.
Air in the rail
The top is cold and the rail gurgles. The towel rail has a bleed valve at the top, and bleeding should be repeated after a few days of operation.
Electric element with both valves closed
Water expands when heated. Manufacturers therefore require that, with the flow closed, water from the rail can expand into the expansion vessel, and they prohibit running the water and electric heating at the same time. The valve on the return should be operable only with a tool, so that nobody closes it by mistake.
The rail is not completely full
An electric element exposed to air overheats and the rail heats only at the bottom. Manufacturers require the rail to be always full and bled.
Weak fixing
A rail loaded with wet towels and children hanging on it works loose over time and pulls on the valve joints.
A socket below the rail
Water dripping from towels falls straight onto the socket. Manufacturers explicitly prohibit this.
How to check the finished work
- the rail is level and firm and does not move when pulled,
- when the heating is on, it is warm over its full height, top and bottom,
- the valve joints are dry even after several days of operation,
- the valves can be opened and closed and you know which is which,
- the other radiators in the house heat as well as before,
- with an electric element: switching on and off works, the cable is not taut or running under the rail, and you have been told which valve may be closed,
- the system pressure after bleeding matches the specification for your boiler.
For DIYers: what you can and cannot do
Replacing a towel rail with the same type and the same centres in a house is within reach of a skilled amateur who knows how to drain, refill, pressurise and bleed the system. In a block of flats, work on the riser is a matter for the building manager and a professional. Connecting the electric element to the fixed wiring and any electrical work in the bathroom must be done only by a qualified, licensed electrician. If you are doing it yourself:
- Before buying, measure the centres and position of the pipe outlets and compare them with the rail's technical data sheet.
- Fix the brackets into masonry or a noggin, not just into plasterboard.
- Use seals and valves designed for heating, and do not overtighten joints on plastic parts.
- After filling, bleed the rail, top up the pressure and bleed again once it has heated up.
- Switch on the electric element only when the rail is full and bled.
Frequently asked questions
The guide price for labour in the price list is €120.00 per piece. The rail, valves and electric element are paid for separately. It costs more if pipes have to be moved, the riser in a block of flats has to be drained or the rail is fixed to plasterboard without a noggin.
Yes, if the centres and position of the outlets allow it. If the centres differ, the pipes are adapted, either by extending them or by chasing them into the wall.
The rail has two connections in the middle of the bottom, 50 mm apart. It is connected through a twin valve, and the pipes from the wall or floor must come out at exactly these centres.
Yes, if the rail is a dual-fuel model and the element is designed for it. The rail must be full and bled, the water must have room to expand, and the water and electric heating must not run at the same time.
Most often there is air in it, the flow is weak because the system is not balanced, or the water temperature is too low. With an electric element, the cause can also be a rail that is not completely full.
For many models manufacturers recommend at least 150 mm above the floor. The final height depends on the position of the pipes and on being able to hang towels comfortably.
If the rail has isolating valves, it is enough to close them and drain only the rail. If there are none or they leak, the whole system is drained, or in a block of flats the riser.
Not inside the bath or shower area or above them. Some manufacturers do not approve zone 1 either, others allow only a fixed connection in zones 1 and 2. The position is assessed by an electrician in line with local wiring regulations.
Related work
When and how to drain a central heating system, what to watch for with radiators and underfloor heating, and how to refill and bleed it.
How a radiator is taken off the wall and refitted, what makes the job harder, what to consider in a flat and how to check the finished work.
How a radiator is boxed in with plasterboard, timber, MDF or metal, what to watch with airflow and valves, and how to check the finished cover.
How underfloor heating pipes are covered with screed, which screed to choose, why the pressure test matters and how to heat the floor up for the first time.
How a floor chase for heating pipes is cut, what makes the job harder, what to watch for in a block of flats and how to check the finished work.
How radiator valves are fitted and replaced, which valve types to choose, common mistakes to avoid and how to check the finished work.
Blog
Price the whole project, not just one job
Choose items from all trades and NUMIQ turns them into a quote for your own project or your customer's project.